Open bids › Energy efficiency, HVAC and lighting
Clearfield Job Corps Center Design-Build (D-B) Roof & HVAC Replacement
LABOR, DEPARTMENT OF
Saving is free and needs an account; browsing never does.
- Who may bid
- Total small-business set-aside a certification is required to bid
- Closes
- Nov 24, 2026 (closes tomorrow)
- Posted
- Nov 10, 2026
- Type
- Sources sought
- Agency
- LABOR, DEPARTMENT OF · OFFICE OF THE ASSISTANT SECRETARY FOR ADMINISTRATION AND MANAGEMENT
- Place of performance
- Clearfield, UT
- Solicitation number
- 1605AE-27-N-00001
- NAICS
- 236220 · Nonresidential building construction
- PSC
- Y1CZ
- Source
- SAM.gov daily extract (Federal)
Summary from the notice
TITLE: Sources Sought – Design-Build (D-B) Services for the Automotive (United Auto Workers - UAW) Building E9 Roof Replacement, HVAC Replacement and Seismic Upgrades at the Clearfield Job Corps Center The US Department of Labor, Office of Job Corps Acquisition Services, has a requirement for a qualified firm to provide design/build services that include, but are not limited to, the complete design and construction for the replacement of the existing roofing system including the roof eaves, overhangs and the roof drainage systems, roof HVAC curbs, pipe penetrations, flashings, roof edge pieces, etc.
as needed to provide a weathertight roof system. THIS IS A SOURCES SOUGHT NOTICE. In accordance with Revolutionary FAR Overhaul (RFO) 10.001(b), this notice is issued for the purpose of conducting market research. Market research is being conducted to determine if there are potential small businesses with the capacity and experience to perform the required work.
This Notice is not to be misconstrued as an Invitation for Bid or Request for Proposal. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the Government assumes no financial responsibility for any costs incurred.
Read full notice
The full extent of the work will be described in the solicitation, which may follow at a later date.
However, a summary of the services to be performed is provided as follows: The work includes design-build (design and construction) services for the complete design and construction for the phased replacement of the existing ballasted built-up roofing system with a new EPDM roofing system including roof eaves, overhangs, roof drainage systems, roof HVAC curbs, pipe penetrations, flashings, roof edge pieces, etc.
as needed to provide a weathertight roof system for the Automotive (UAW) Building E9 which totals approximately 120,000 gross square feet (GSF). Also included is the design and construction of the replacement of roof mounted HVAC units and associated ductwork, replacement of roof mounted exhaust fans, and seismic upgrades to the building structure to bring it up to current seismic codes for Utah.
The roof design shall meet current allowable wind loads for Clearfield, Utah. Work shall be in accordance with the National Roofing Contractors Association (NCRA) recommendations for the type of roofing system specified. The NAICS code for this project is 236220 with a size standard of $45 Million. The magnitude of construction for this project is more than $10 million.
Firms interested in this requirement are requested to submit a statement of qualifications. Your statement of qualifications shall demonstrate the capacity of your firm to perform the services described above, and should include the following information: 1.
Provide two (2) project examples where the D/B Contractor has completed (substantially or final) the design and replacement of single-ply Ethylene Propylene Diene Monomer (EPDM) roofing systems within the last five (5) years. 2.
Provide two (2) project examples where the D/B Contractor has completed (substantially or final) the design and replacement of roof mounted HVAC units and associated ductwork and air devices within the last five (5) years. 3. Provide two (2) project examples where the D/B Contractor has completed (substantially or final) the design and seismic upgrades in occupied buildings within the last five (5) years.
Project examples shall include the location of the project, the project owner, and a brief description of the services performed. Your synopsis should also include the date of contract award, the original and final date of contract completion. Using the previous project examples indicate the original contract price and final contract value.
The Government will evaluate market information to ascertain potential market capacity to 1) provide services consistent in s…
More open bids like this
-
Design Build (DB) Requirement for Land Port of Entry Modernization Project in Limestone, Maine
GENERAL SERVICES ADMINISTRATION -
Design-Build Renovation of Building 164, Outdoor Recreation Center, Homestead Air Reserve Base, Florida
DEPT OF DEFENSE -
Program Solicitation W9127826SC001 Deployment Center/Flight Line Dine - Crash/Fire Rescue Station - Demo Hangar 4 Tyndall Air Force Base, Florida (Bay County) Progressive-Design-Build OT
DEPT OF DEFENSE -
Z2DA--523A4-CSI-288 3.0T MRI Site Prep - Design Build West Roxbury VA Medical Center (VAMC_ West Roxbury, MA
VETERANS AFFAIRS, DEPARTMENT OF -
Replace Radiant Heating System and Exhaust Fan, Bldg. 362 Dam Neck Annex, Virginia Beach, VA
DEPT OF DEFENSE