Sewage Ejector and Line Assessment
DEPT OF DEFENSE
Saving is free and needs an account; browsing never does.
- Who may bid
- Full and open anyone registered may bid
- Closes
- Oct 28, 2026 (closes in 19 days)
- Posted
- Sep 28, 2026
- Type
- Solicitation
- Agency
- DEPT OF DEFENSE · DEPT OF THE ARMY
- Solicitation number
- W912BV26QA069
- NAICS
- 237110 · Utility system construction
- PSC
- J045
- Source
- SAM.gov daily extract (Federal)
Summary from the notice
This scope of work requires the contractor to locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and its associated distribution box, with mandatory Government presence during all site inspections. Key tasks include installing concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, exposing and inspecting the distribution box and its 2009 leach field connections, and extending the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing, and any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates.